Camera for Glass furnace
 2025/01/16 | View:523

The Camera for Glass Furnace is made of 310S stainless steel and features an air-cooled protective tube with a corrosion-resistant, high-temperature-resistant coating on the outer layer. It can be directly inserted into the furnace (up to 2000℃) for continuous real-time monitoring. Equipped with a 3-million-pixel high-temperature camera and a sapphire high-temperature lens, the system can clearly monitor materials, flames, bubbles, and other critical conditions inside the furnace.


Camera for Glass Furnace-site-photo-1
Camera for Glass Furnace-site-photo-2
Camera for Glass Furnace-effect diagram


Product features

■ Using a megapixel high-definition image sensor, the furnace image is clearer;

■ Unique wind and water cooling protection, so that the probe can be used in 2000℃ environment;

■ Image signal digital TCP / IP network output, image without interference;

■ The probe adopts the pneumatic exit device;

■ The probe can automatically exit the furnace protection under the condition of over-temperature, gas break and power failure;

■ The probe is made of special high temperature resistant stainless steel material, with high temperature resistance and corrosion resistance;

■ Fixed installation on the kiln for full monitoring.

Camera for Glass Furnace-site-photo-3


Product superiority     

■ Online observation of the flame burning in the furnace;

■ Online observation of the entire melting process of the glass liquid in the furnace;

■ High reliability structural design, the equipment is basically maintenance-free;

■ High-performance HD image sensor allows clear images in the furnace;

■ For different kilns, we can provide probes of different sizes to meet on-site use requirements.


System technical parameters Requirements for cooling water and cooling gas

■ Probe maximum temperature: ≤2000℃ (under wind and water cooling conditions) Image pixels: 3 million

■ Field of view angle: 45°~90°

■ Observation method: direct view

■ Data output method: TCP/IP network

■ Effective usable length of probe: 250mm~600mm (optional)

■ gas

1. Pressure: 0.4 to 0.7MPa (i. e. 4-7 kg)

2. Flow rate: 10 to 20 m ³ / h (m ³ / h is cubic meters / hour)

3. temperature:20℃ to 35℃

4. Clean instrument gas must be used, otherwise unclean cooling gas air will pollute the lens and blur the lens.

■ water

1. Water removing removal (soft water)

2. Water inflow pressure: 3-6bar (namely 3-6 kg)

3. Temperature: ≤35℃ temperature

4. Water flow: not less than 15 L/min (L/min "liter / per minute")